Your SICK ID gives you access to our extensive range of services. This includes direct online orders, price and availability checks, and access to our digital services.
Every single measurement degree (TiM has a resolution of 0.33° or 1°) consists of 84 single measurement points that are accumulated for one measurement value output.
Related Products
TiM
Table of Contents
Every single measurement degree (TiM has a resolution of 0.33° or 1°) consists of 84 single measurement points that are accumulated for one measurement value output.
A 1°-device has 84 single measurement points per 1°.
A 0.33°-device has 84 single measurement points per 0.33° (three times higher measurement frequency than a 1°-device).
Example for a 1° device: If the mirror of the scanner is at the position of 45 degrees, then the scanner starts with the 84 laser pulses at the mirror position of 45 degrees until a short step before 46 degrees. Then, it calculates the distance value over these points and returns one measurement value for this 45° position. The next set of 84 new measurement points starts at the next angular degree, in this example at 46°.