Your SICK ID gives you access to our extensive range of services. This includes direct online orders, price and availability checks, and access to our digital services.
There are basically shielded and unshielded cables available.
At cable lengths, less then 200 mm, inside the motor, it is possible to use unshielded cables.
At cable lengths, above 200 mm, inside the motor, we suggest to use shielded cables.
Variances of unshielded cables
Length of the cable
Diameter and size of the heat shrink at the connector
Amount of wires (2 or 4)
Variances of shielded cables
Length of the cable
Type of shield connection (strain relief, extra grounding wire, shield on pin 4)
Variances of the cable exit (Motor connector side)
General information to the Hiperface DSL encoder cables
The Hiperface DSL wires are on pin 2 and pin 3
Pin 4 is used at the EKS36 / EKM36 as shielding contact
Pin 1 and pin 4 is used at the ENS35 / ENM35 for the temperature sensor
Overview pin assignment:
pin
colour
EKx36
EFx50 / EEx37 / EDx35
ENx35
1
red / --
Temp.1
2
grey
DSL +
DSL +
DSL +
3
green
DSL -
DSL -
DSL -
4
blue / none
Housing
Temp. 2
2 wires cables, without shielding
DOL-0B02-G0M2XC1 (2062083) Cable (200mm) without shielding/jacket, with heat shrink at the connector Diameter (heat shrink): 3.7 mm Length (heat shrink): 70 mm The cable is designed for the EKS36 / EKM36
DOL-0B02-G0M3XC1 (2091818) Cable (300mm) without shielding/jacket, with heat shrink at the connector Diameter (heat shrink): 3.7 mm Length (heat shrink): 70 mm The cable is designed for the EKS36 / EKM36
DOL-0B02-G0M4XC1 (2086286) Cable (400mm) without shielding/jacket, with heat shrink at the connector Diameter (heat shrink): 3.7 mm Length (heat shrink): 70 mm The cable is designed for the EKS36 / EKM36
DOL-0B02-G0M2XC2 (2079920) Cable (200mm) without shielding/jacket, with heat shrink at the connector Diameter (heat shrink): 2.8 mm Length (heat shrink): 25 mm The cable is designed for the EFS50 / EFM50
4 wire cables without shielding
DOL-0B04-G0M2XC1 (2058333) Cable (200mm) without shielding/jacket, with heat shrink at the connector Diameter (heat shrink): 3.8 mm .. 4.2 mm Length (heat shrink): 70 mm The cable was designed for the EKS36 / EKM36 with 4 wire DSL (which is phased out)
DOL-0B04-G0M4XC1 (2076293) Cable (400mm) without shielding/jacket, with heat shrink at the connector Diameter (heat shrink): 3.8 mm .. 4.2 mm Length (heat shrink): 70 mm The cable was designed for the EKS36 / EKM36 with 4 wire DSL (which is phased out)
DOL-0B04-G0M2XS10 (2140378) Cable (200mm) without shielding/jacket, The cable was designed for the ENS36 / ENM36 with has the temperature sensor on pin 1 and pin 2
2 wire cables with shielding
DOL-0B02-G0M3AC2 (2108944) Shielded cable (335 mm) with shield connection at the strain relief. Designed for the EDx35, EEx37
DOL-0B02-G0M2XS09 (2092832) Shielded cable (300 mm) with heat shrink at the connector. The cable has a grounding wire (70mm) with a cable shoe, connected to the shielding
DOL-0B02-G0M2XS02 (2104097) -> customized Special shielded cable (260 mm) with heat shrink at the connector and a special pin outlet The cable has a grounding wire (70mm) with a cable shoe, connected to the shielding
DOL-0B02-G0M2XS01 (2104098) -> customized Special shielded cable (210 mm) with heat shrink at the connector and a special pin outlet The cable has a grounding wire (70mm) with a cable shoe, connected to the shielding
DOL-0B02-G0M2XS04 (2108599) -> customized Special shielded cable (370 mm) with heat shrink at the connector and a special pin outlet The cable has a grounding wire (70mm) with a cable shoe, connected to the shielding
DOL-0B02-G0M2XS05 (2110386) -> customized Special shielded cable (370 mm) with heat shrink at the connector and a special pin outlet The cable has a grounding wire (70mm) with a cable shoe, connected to the shielding
3 wire cable (2 wire + housing) with shielding
DOL-0B03-G0M4XC1 (2087314) Shielded cable (430 mm) with shield connection on pin 4 of the connector. Designed for the EKS36 / EKM36 with GND on Pin 4 (hardware "B" and later)