Convert PAC50 IO-Link process data into bar

Calculate the pressure value from the 2-byte raw process data using the gradient, zero point offset, and given formula.
Related Products

Table of Contents

1. Convert the process data from decimal to binary, remove the two switching outputs (bit 0 and bit 1) from the
numerical value, and convert it back into a decimal value.

2. Calculate the pressure value P using the following formula, incorporating the process data variable (PDV,
Index 40), the gradient / slope factor (PDGradient, Index 69), and the zero offset (PDOffset, Index 70):

Keywords:
pac50 io link, convert pac50 io link, process data into bar