IO-Link: Is normal ISDU / service data communication possible in parallel to Data Storage?

No “On-Request Data" transfer possible during upload of Data Storage content.

Table of Contents

The upload of a data set from the IO-Link device into the DS of the IO-Link master may take from a few milliseconds up to some seconds – depended on the amount of data and baud rate.
During this time no other “On-Request Data” (sometimes called Service Data) could be read or written. Some IO-Link masters provide a feedback if the transfer is done or even in progress. Other provide no information. This is completely IO-Link master specific.
SICK function blocks have no possibility to provide this information. 
After an DS upload is triggered this upload time has to be considered.