Protocol / Interface Purpose Pros Cons Links 
CoLa A (incl. LMDscandata)
  • Device configuration (TCP)
  • Measurement data streaming (TCP)
  • Human readable
  • Fast configuration for tests
  • Support by almost all devices
  • Event driven
  • Large overhead for data streaming
CoLa B (incl. LMDscandata)
  • Device configuration (TCP)
  • Measurement data streaming (TCP)
  • Small data overhead
  • Simple PLC parsing possible
  • Event driven
  • Not human readable
Robot Operating System (ROS)
  • Device configuration
  • Measurement data visualization 
  • Measurement data streaming into a ROS environment
  • Simple configuration and data recording on ROS
  • ROS 1 and ROS 2 Support
  • All devices supported
  • Requires ROS environment
GUI - SOPAS ET
  • Device configuration
  • Measurement data visualization
  • Backup & restore parameter set
  • Firmware update
  • Fast configuration
  • Help texts available for some configuration parameter
  • Filter effect is directly  visualized 
  •  Windows only
GUI - SOPASair (Webserver)

 

  • Measurement data visualization
  • Diagnostic
  • Webserver based
  • Field-/Measurement visualization
  • no backup & restore
  • no firmware update

 